The Potter PAD200-PD Photoelectric Smoke Detector is an intelligent addressable smoke detector designed for compatible Potter fire alarm control panels using the PAD protocol. It uses photoelectric sensing technology to detect smoke while providing individual device identification and system monitoring.
The PAD200-PD incorporates a low-profile design, onboard status indication, and rotary address switches for straightforward field configuration. It is intended for open-area smoke detection applications on compatible Potter addressable systems.
Product Functions
- Provides intelligent addressable smoke detection
- Uses photoelectric sensing technology
- Designed for Potter PAD protocol systems
- Provides individual point identification
- Uses rotary address switches
- Provides detector status indication
- Supports detector sensitivity monitoring
- Provides drift compensation
- Supports maintenance indication
- Uses plug-in detector bases
- Supports compatible remote LED indication
- Provides low standby current
- Designed for compatible Potter addressable control panels
Photoelectric Smoke Detection
The PAD200-PD uses photoelectric sensing technology to detect airborne smoke particles.
Smoke entering the detector’s optical chamber changes the amount of light reaching the sensing element. The detector processes this information and communicates the condition to the compatible Potter fire alarm control panel.
Photoelectric detection is particularly effective for detecting smoke associated with slow, smoldering fires.
Intelligent Addressable Operation
Each PAD200-PD operates as an individually identifiable device on the Potter signaling line circuit.
The fire alarm control panel can identify the exact detector reporting an alarm, trouble, or maintenance condition rather than indicating only a conventional detection zone.
Rotary Addressing
The PAD200-PD uses rotary address switches for device configuration.
The detector supports addresses:
1–127
The address is selected directly at the detector, simplifying commissioning, troubleshooting, and device replacement.
Drift Compensation
The PAD200-PD supports automatic compensation for gradual changes in detector sensitivity caused by environmental conditions and contamination.
This helps maintain stable smoke detection performance while reducing unwanted alarms associated with normal detector aging or dust accumulation.
Status Indication
The detector incorporates LED status indication that provides local confirmation of detector operation.
The LEDs can indicate normal communication, alarm, and other detector conditions according to the connected Potter fire alarm control panel.
Detector Base Compatibility
The PAD200-PD uses compatible Potter PAD Series detector bases, including:
PAD100-4DB — 4-inch Detector Base
PAD100-6DB — 6-inch Detector Base
PAD100-RB — Relay Base
PAD100-IB — Isolator Base
PAD100-SB — Sounder Base
The plug-in design allows the detector head to be removed or replaced without disturbing the field wiring connected to the base.
Electrical & Detection Information
Model: PAD200-PD
Device Type: Intelligent Photoelectric Smoke Detector
Sensing Technology: Photoelectric
Protocol: Potter PAD
Operating Voltage: 24 VDC nominal
Address Range: 1–127
Addressing: Rotary Switches
Operating Temperature: 32°F to 120°F / 0°C to 49°C
Relative Humidity: Up to 93%, non-condensing
Status Indicator: LED
Detector Base: Separately ordered
Exact electrical characteristics and panel compatibility should follow the applicable Potter technical documentation.